Specific Laser Technology Results After Best Lasik Procedure In Chicago
For all surgical process that involves a laser, the doctor uses cool lasers so that any damage to the surrounding tissues is eliminated. All such surgeries are performed in the state of the art clinics have the latest and most innovative gadgets for the Best Lasik procedure in Chicago. The lasers that are used emit a cool beam of an ultraviolet ray having a particular wavelength which is ideally 193 nanometers. This is used to remove the corneal tissue precisely to produce the best result. This removal and scraping of the surface tissue of the cornea result in reshaping and leveling the corneal surface thereby enabling light to focus properly, and you have a clear and improved vision.
The Working Process
These lasers are perfectly designed to allow passing high energy pulses of the ultraviolet ray to penetrate through only a small portion of the cornea. Such lasers also have the ability to remove as little as 0.25 microns of the corneal tissue at a time. Such precision only enables the Best Lasik treatment in Chicago which corrects the nearsightedness of a patient by flattening the surface of the cornea. It can also correct farsightedness by steepening the surface of the cornea as well. Apart from that such treatment procedure is also able to cure astigmatism by rectifying any irregularities in the cornea to give a more symmetrical shape.
Use of Technology
It is all due to the extensive use of the latest technology in the surgical process that produces the Best Lasik treatment in Chicago with the most desired outcome. Development of technology and use of computer controlled settings are effective to correct the refractive error. However, minute it may be. All the required specifications and measurements are fed to the computer by the qualified and experienced surgeon after conducting proper tests. The machine does the rest of the job according to the pattern and quantity of tissue removal required by each patient.
Automatic Tracking And Control
The best lasers have automated eye tracking system and monitor eye movement so that the laser beam can be targeted exactly to the required spot during the surgery which produces best results. This also helps in reducing any complications that may arise after the surgery making it a popular process. With such innovative equipment, the patient gets the ultimate comfort and also Best Lasik treatment in Chicago. Doctors can control the timing of laser beam according to the requirement which ranges from 20 to 60 seconds or even longer depending on the amount of tissue to be removed and the refractive error. This increases the level of comfort.
Size of Pupil And Ablation Speed
If the size of the pupil is large, then it might affect the outcome of laser treatment for correcting vision. If the expansion of the pupil in low light is beyond the diameter of the treatment zone on the cornea, you may experience halos and glares at night. Such unusual expansion and contraction of the pupil are not desired during the surgery. All such problems are overcome with such lasers to produce the best results. Visit Here: Kraff Eye Institute
The Working Process
These lasers are perfectly designed to allow passing high energy pulses of the ultraviolet ray to penetrate through only a small portion of the cornea. Such lasers also have the ability to remove as little as 0.25 microns of the corneal tissue at a time. Such precision only enables the Best Lasik treatment in Chicago which corrects the nearsightedness of a patient by flattening the surface of the cornea. It can also correct farsightedness by steepening the surface of the cornea as well. Apart from that such treatment procedure is also able to cure astigmatism by rectifying any irregularities in the cornea to give a more symmetrical shape.
Use of Technology
It is all due to the extensive use of the latest technology in the surgical process that produces the Best Lasik treatment in Chicago with the most desired outcome. Development of technology and use of computer controlled settings are effective to correct the refractive error. However, minute it may be. All the required specifications and measurements are fed to the computer by the qualified and experienced surgeon after conducting proper tests. The machine does the rest of the job according to the pattern and quantity of tissue removal required by each patient.
Automatic Tracking And Control
The best lasers have automated eye tracking system and monitor eye movement so that the laser beam can be targeted exactly to the required spot during the surgery which produces best results. This also helps in reducing any complications that may arise after the surgery making it a popular process. With such innovative equipment, the patient gets the ultimate comfort and also Best Lasik treatment in Chicago. Doctors can control the timing of laser beam according to the requirement which ranges from 20 to 60 seconds or even longer depending on the amount of tissue to be removed and the refractive error. This increases the level of comfort.
Size of Pupil And Ablation Speed
If the size of the pupil is large, then it might affect the outcome of laser treatment for correcting vision. If the expansion of the pupil in low light is beyond the diameter of the treatment zone on the cornea, you may experience halos and glares at night. Such unusual expansion and contraction of the pupil are not desired during the surgery. All such problems are overcome with such lasers to produce the best results. Visit Here: Kraff Eye Institute